This is the first issue of our FDA 510(k) China Monthly, covering October 2026, with data from FDA's public openFDA interface as of the openFDA update dated 2 November 2026. Three findings: applicants based in China received 61 510(k) clearances in October 2026, second only to the United States; their January–October 2026 total of 510 was up 16.7% on the same period of 2025, far faster than the total; and October's Chinese clearances clustered in two panels, led by powered wheelchairs (product code ITI) and laser surgical instruments (GEX).

Definitions: a "clearance" is a Substantially Equivalent decision; a "Chinese applicant" has the openFDA country code CN; records are assigned to the month of the FDA decision date. We publish aggregates only, with no company names or 510(k) numbers.

Key findings

  • 61 clearances in October, ranked second. Of 295 510(k) decisions in October 2026, 155 went to US applicants and 61 to Chinese applicants: 20.7% of the total and more than three times third-placed Korea (18).
  • China up, total down. Compared with September 2026, Chinese applicants gained 6 clearances while the total fell by 25. Compared with October 2025, Chinese applicants gained 13 while the total fell by 13.
  • Most of the year's growth came from China. From January to October 2026 the total rose by 103 over the same period of 2025. Chinese applicants added 73 of those (up 16.7%), while all other applicants combined added only 30 (up 1.3%).
  • Concentrated by panel, product and city. Two panels account for 28 of the 61 clearances, two product codes (ITI and GEX) for 15, and Shenzhen alone for 14.
  • Median review time: 138 days. Calendar days from FDA receipt to decision, including time applicants spend answering FDA's questions.

October totals and country ranking

Ranked by the country code in the applicant's postal address (share = count ÷ 295):

RankCountry/region (code)ClearancesShare
1United States (US)15552.5%
2China (CN)6120.7%
3Korea (KR)186.1%
4Germany (DE)93.1%
5United Kingdom (GB)72.4%
6Israel (IL)62.0%
7France (FR)51.7%
7Taiwan, China (TW)51.7%
9Switzerland (CH)41.4%
—All other countries and regions (3 or fewer each)258.5%

From 10th place down, no country or region had more than 3, with several ties at 3, including Australia, Belgium and Japan, so they are not ranked individually. Outside the United States, China's 61 clearances were 7 more than the combined 54 of the seven countries and regions ranked 3rd to 9th.

13-month trend

MonthAll applicantsChinese applicantsChinese share
2025-103084815.6%
2025-112073918.8%
2025-122915920.3%
2026-012383615.1%
2026-022173817.5%
2026-033014916.3%
2026-043177423.3%
2026-052815419.2%
2026-063256118.8%
2026-072833311.7%
2026-082534919.4%
2026-093205517.2%
2026-102956120.7%

Over these 13 months, Chinese applicants ranged from 33 clearances (July 2026) to 74 (April 2026). October 2026's 61 ties with June 2026 for second place, and its 20.7% share is second only to April 2026's 23.3%. Monthly counts swing widely, so cumulative totals are a better guide to direction.

January–October cumulative comparison

GroupJan–Oct 2025Jan–Oct 2026ChangeChange (%)
All applicants2,7272,830+103+3.8%
Chinese applicants437510+73+16.7%
All other applicants2,2902,320+30+1.3%
Chinese share16.0%18.0%+2.0 points—

Chinese applicants averaged 51.0 clearances a month from January to October 2026, against 43.7 in the same period of 2025. Because openFDA has a loading lag, any October decisions added in later updates would raise the January–October 2026 figures accordingly.

Where Chinese clearances concentrate: panels and product codes

By panel

openFDA's advisory committee field gives, for each product code, the medical specialty panel under which that device type was originally classified; it may differ from the 510(k) review panel in openFDA's separate review advisory committee field. The 61 Chinese clearances in October 2026 break down as follows:

PanelClearances
General, Plastic Surgery16
Physical Medicine12
Radiology6
Cardiovascular5
Gastroenterology, Urology3
Neurology3
Dental3
Clinical Chemistry3
General Hospital3
Anesthesiology2
Unknown2
Ear, Nose, Throat1
Ophthalmic1
Orthopedic1

Within General and Plastic Surgery, three codes (GEX, OHS and FTC) account for 12 of the 16. Within Physical Medicine, ITI accounts for 8 of the 12 and OAP for 2. Going by FDA's device names, GEX, OHS, FTC and OAP are all light-based or laser devices. Together they total 14, close to a quarter of the October Chinese count.

Product codes (15 listed)

The 61 clearances span 41 product codes: the 15 codes in the table below account for 35, and the other 26 codes have one clearance each. From 9th place down every code has one clearance, so tied codes are listed in data-file order.

CodeFDA device name21 CFRClearances
ITIWheelchair, Powered890.38608
GEXPowered Laser Surgical Instrument878.48107
OHSLight Based Over The Counter Wrinkle Reduction878.48103
IYNSystem, Imaging, Pulsed Doppler, Ultrasonic892.15502
FTCLight, Ultraviolet, Dermatological878.46302
NBWSystem, Test, Blood Glucose, Over The Counter862.13452
OAPLaser, Comb, Hair890.55002
DXNSystem, Measurement, Blood-Pressure, Non-Invasive870.11302
DYBIntroducer, Catheter870.13401
DQAOximeter870.27001
BTAPump, Portable, Aspiration (Manual Or Powered)878.47801
FJLResectoscope876.15001
PKLHemostatic Metal Clip For The GI Tract876.44001
ETAReplacement, Ossicular Prosthesis, Total874.34951
NUHStimulator, Nerve, Transcutaneous, Over-The-Counter882.58901

All 15 codes in the table are Class II devices, and the three over-the-counter codes (OHS, NBW and NUH) account for 6 clearances. SUNGO's powered wheelchair testing is carried out at the laboratory of Hefei SUNGO Medical Technology Co., Ltd., where the ISO 7176 parts listed on its certificates fall within its CNAS (L24279) and IAS (TL-1119) accreditation scopes respectively (the two certificates do not list identical parts; the certificate schedules govern), and ANSI/RESNA WC-1 and WC-2 fall within its IAS scope only. See the electric wheelchair testing page.

Submission type and third-party review

Of the 61, 58 were Traditional 510(k)s and 3 were Special 510(k)s; there were no other types. FDA's Special 510(k) guidance describes it as an optional pathway for certain well-defined modifications that a manufacturer makes to its own legally marketed device. One record carries openFDA's third-party flag (third_party_flag) "Y" and the other 60 carry "N". Under FDA's Third Party Review Program, manufacturers of certain devices may submit their 510(k) to an FDA-recognized third party for review instead of directly to CDRH; FDA still makes the final decision.

Cities

Counted from the city field of the applicant's postal address (capitalization standardized, spelling variants not merged), the top 12 city names were as follows. From 10th place down each has one clearance, and tied names are listed in data-file order.

City (as spelled in the data)Clearances
Shenzhen14
Hangzhou6
Chuzhou5
Suzhou4
Nanjing3
Shanghai2
Langfang2
Guangzhou2
Beijing2
Suzhou New District1
Xian1
Mingguang1

Shenzhen's 14 are 23.0% of the 61. The top 12 city names total 43; the other 18 clearances sit under other city names, one each. Spellings such as "Suzhou" and "Suzhou New District" are not merged, and a city's count may reflect only a handful of companies, so this is not a ranking of regional industry size.

Review days

Review days are the FDA decision date minus the FDA receipt date (openFDA fields decision_date and date_received), in calendar days. For the 61 Chinese clearances in October 2026, the median was 138 days, the lower quartile 82 and the upper quartile 220, with a minimum of 1 day and a maximum of 447.

Three caveats. First, calendar days include the time applicants spend answering FDA's requests for additional information, so this is not FDA's own review time. Second, a third-party-reviewed submission reaches FDA only after the third party's review, so days counted from FDA receipt leave out that stage and can be much shorter; one October Chinese clearance carries the third-party flag "Y". Third, cases vary widely, so the median is more informative than the mean.

Methodology and limitations

  • Source and date: openFDA device/510k, as of the openFDA update of 2 November 2026, retrieved 11 November 2026. openFDA lists its update frequency as monthly and records load with a lag, so some late-October decisions may not yet be included and monthly figures may shift slightly in later updates. When citing, please state the data date; FDA's official databases are authoritative.
  • Chinese applicant: the country code comes from the applicant's postal address (openFDA field definitions); filings made through entities outside China are not counted under CN.

How to look this up in our database

  1. Product codes: open our FDA product code library, browse by panel (for example General and Plastic Surgery or Physical Medicine) and open a code page. It shows the device class, 21 CFR section, marketing pathway and FDA's classification definition, plus the 510(k)s in our three-year data window with the date of the newest one. For later records, check FDA's 510(k) database.
  2. Classification regulations: our regulatory library covers the 21 CFR classification parts, such as 21 CFR 890 and 21 CFR 878, with a summary and a link to the official eCFR text.
  3. Chinese companies: By country › China lists Chinese companies with their record counts in China, the EU, the US and other markets, and each company page has a US section showing FDA-listed device types and 510(k) clearances by year. You can also use site search to look up a company or product name.
  4. Individual records and reproduction: FDA's 510(k) database can be searched by product code, decision date range, panel, 510(k) type and third-party review. To reproduce our numbers, query the openFDA 510(k) interface by a decision_date month range, then filter by country_code.

FAQ

Who counts as a "Chinese applicant"? Are Taiwan, China and Hong Kong, China included?

We count records with the openFDA country code CN. According to openFDA's field definitions, the applicant is the manufacturer that submits the 510(k), also known as the sponsor, and the country code comes from its postal address. Taiwan, China (TW) and Hong Kong, China (HK) have separate codes and are not included, and submissions through overseas entities such as US subsidiaries fall outside CN.

Can the 138-day median be used to estimate how long my own 510(k) will take?

Only as a broad reference. It counts calendar days including applicants' response time, and October cases ranged from 1 to 447 days. A single project's timeline depends on the submission type, the completeness of the file and the exchanges with FDA. FDA's Premarket Notification 510(k) page explains the submission types and process.

Where can I see which products were cleared under a given code?

Start with the code page in our product code library, which lists 510(k)s within our data window. For October records, search FDA's 510(k) database by product code and the decision date range 2026-10-01 to 2026-10-31.

About SUNGO Lab: What We Test

SUNGO Lab is made up of two independent companies, Shanghai SUNGO Medical Technology Co., Ltd. and Hefei SUNGO Medical Technology Co., Ltd., and focuses on medical device testing. Our core service lines are:

  • Wheelchair and mobility aid testing (Hefei laboratory): manual and powered wheelchairs, scooters, walking aids and crutches to the ISO 7176 series (excluding Part 19 crash testing and Part 20 standing wheelchairs), ANSI/RESNA WC-1/WC-2, EN 12183, EN 12184, the GB/T 18029 series and GB/T 12996-2024. Which accreditation (CNAS, CMA or IAS) covers each standard is as listed in our certificate scopes. See Wheelchair testing for FDA 510(k) and RESNA.
  • Medical electrical safety and EMC (Hefei laboratory, IAS accredited, certificate TL-1119): IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, IEC 60601-1-11 and ISO 80601-2-69, with the corresponding Chinese standards GB 9706.1 and YY 9706.102.
  • Testing for registration in China and overseas: we plan testing to the standards your target market requires (NMPA, FDA 510(k), EU CE marking and others) and issue the test reports for your submission; whether a report is accepted is decided by the regulator.

Our Shanghai laboratory also tests medical masks, gloves, surgical gowns, sterile packaging and sterilization-related items. CNAS and IAS are both signatories to the ILAC MRA. Send your product, target markets and standards through our contact page and we will confirm which laboratory and which accredited scope covers each test.