GB 47741-2026, Safety technical specification for batteries used in electrically powered wheelchair, is a mandatory Chinese national standard. It was published on 25 May 2026 and takes effect on 1 June 2027, with the Ministry of Industry and Information Technology (MIIT) as both the competent and the responsible department. Two related mandatory national standard projects, one for electric wheelchair chargers and one for the electric wheelchair itself, were still out for public comment as of 13 November 2026. This article sets out the official information and timeline for all three documents, where to read the full text and the comment drafts, what manufacturers can do before the implementation date, and how to look up related standards in our database.

Key points

  • GB 47741-2026 is a mandatory national standard in the "safety" category. It was published on 25 May 2026 by the State Administration for Market Regulation (SAMR) and the Standardization Administration of China (SAC), and takes effect on 1 June 2027.
  • Under China's Standardization Law, mandatory standards must be complied with, and products that do not conform to a mandatory standard may not be produced, sold or imported. Which batteries and products the standard covers is defined by the scope in its full text.
  • The full text can be reached from the GB 47741-2026 detail page on the National Public Service Platform for Standards Information. The "view text" link leads to the national standard full-text page, which offers an online preview.
  • The charger project (plan 20254990-Q-339) and the vehicle project (plan 20263144-Q-314) were both listed as "out for public comment" as of 13 November 2026. Their project pages state that each is planned to take effect 12 months after publication, so no implementation date can be fixed yet.
  • Existing test reports against ISO 7176-25, ISO 7176-31 or GB/T 18029.25 do not automatically prove conformity with GB 47741-2026. They need to be compared with the full text of GB 47741-2026, requirement by requirement.

What GB 47741-2026 is: background and scope

On the National Public Service Platform for Standards Information, the basic record for GB 47741-2026 shows plan number 20254992-Q-339, Chinese Standard Classification K82, and ICS 29.220.99 ("other cells and batteries" under electrical engineering). The platform status is "about to be implemented". In other words, the standard is classified with batteries. The charger and vehicle projects discussed below are both classified under ICS 11.180, "aids for disabled or handicapped persons".

The drafting organisations listed on the platform cover a wide range: standards research institutes, rehabilitation aid research and testing bodies, battery makers, electric wheelchair makers, airlines, airport and airport cargo operators, and an e-commerce platform operator. We do not name individual organisations, and we do not draw conclusions about the technical content from this list. The scope, technical requirements and test methods can only be taken from the full text of the standard.

Before GB 47741-2026 was published, testing of electric wheelchair batteries and chargers relied mainly on recommended national standards and international standards, including:

  • GB/T 18029.25-2022, Wheelchairs Part 25: Batteries and chargers for powered wheelchairs, a recommended national standard;
  • ISO 7176-25:2022, covering lead-acid batteries and chargers for powered wheelchairs;
  • ISO 7176-31:2023, covering lithium-ion battery systems and chargers for powered wheelchairs;
  • In the "similar standards" list for GB 47741-2026, the platform also shows two electronics industry standards: SJ/T 11810-2022, a safety technical specification for lithium-ion cells and battery packs for electric wheelchairs, and SJ/T 11811-2022, a general specification for the same products.

These are voluntary recommended or international standards, while GB 47741-2026 is mandatory, so the two groups carry different legal weight. Article 2 of the Standardization Law divides national standards into mandatory and recommended standards and states that mandatory standards must be complied with. Article 10 assigns the proposal, drafting, public consultation and technical review of mandatory national standards to the relevant State Council departments according to their responsibilities. That is why MIIT is the responsible department for the battery standard and the Ministry of Civil Affairs organises the drafting of the vehicle standard.

Exporters should note that Article 26 of the Standardization Law states that the technical requirements for exported products and services follow the contract. If the same model is also sold in China, or if the scope of the standard says otherwise, it needs to be checked separately. Whether a given model falls under GB 47741-2026 depends on the scope in the full text and on the interpretation of the competent authority, not simply on whether the model is labelled for export or for the domestic market.

Battery, charger and vehicle mandatory standards: timeline compared

The table below is based on the National Public Service Platform for Standards Information, with status as of 13 November 2026.

DocumentType and departmentKey datesStatus as of 13 November 2026Where to read the text
GB 47741-2026, Safety technical specification for batteries used in electrically powered wheelchair (plan 20254992-Q-339)Mandatory national standard; MIIT is the competent and responsible departmentPublished 25 May 2026; takes effect 1 June 2027Published; labelled "about to be implemented""View text" on the detail page leads to the online preview on the full-text page
Safety technical specification of chargers for powered wheelchairs (plan 20254990-Q-339)Mandatory national standard project (new standard); drafting organised by MIITAssigned 30 September 2025; project period 22 months; planned to take effect 12 months after publicationOut for public commentProject page provides the comment draft and explanatory note as PDF files
Safety technical specification for electric wheelchairs (plan 20263144-Q-314)Mandatory national standard project (new standard); drafting organised by the Ministry of Civil Affairs and carried out by the wheelchair subcommittee of the national technical committee for rehabilitation and special equipment for persons with disabilities (TC148SC1)Assigned 27 June 2026; project period 8 months; planned to take effect 12 months after publicationOut for public commentProject page provides the comment draft and explanatory note as PDF files

Three things follow from the table. First, the battery standard has fixed publication and implementation dates, with roughly a year between them for preparation. Second, the charger and vehicle projects have not been published, so "12 months after publication" cannot be turned into a date until the publication date is known. Any specific implementation date quoted before then is a guess. Third, each of the three platform pages lists the other two among its "similar standards", which shows that the platform treats them as related. How they will connect technically will only be clear from the references in the final texts, and this article does not discuss the clauses of the comment drafts.

The "similar standards" list on the vehicle project page also shows two projects in the wheelchair series: 20260232-T-314, Wheelchairs Part 25: Lead-acid batteries and chargers for powered wheelchairs, requirements and test methods, and 20242869-T-314, Wheelchairs Part 31: Lithium-ion battery systems and chargers for powered wheelchairs, requirements and test methods. Manufacturers planning battery and charger testing can add both to their tracking list. Check the platform for their progress.

What manufacturers can do before implementation

Before 1 June 2027, battery makers and electric wheelchair makers can prepare in the following order. Each step should be checked against the full text of the standard and announcements from the competent authority.

  1. Read the full text of GB 47741-2026 through the platform's online preview. Start with the scope and confirm which of your battery models and wheelchair models fall within it.
  2. Build a product list: which battery and which charger go with each wheelchair model, which supplier provides each battery, and whether any change of cell or pack is planned.
  3. Ask battery suppliers for conformity evidence against GB 47741-2026, including test reports from appropriately qualified testing bodies. Check that the standard number, edition and sample model in each report match the battery you actually use.
  4. Compare your existing reports against ISO 7176-25, ISO 7176-31, GB/T 18029.25 and similar standards with the full text of GB 47741-2026 item by item. Identify the requirements they do not cover, then decide whether further testing is needed.
  5. Use 1 June 2027 as the milestone for model changeover, stock sell-through and delivery of signed orders. If the standard text or the competent authority sets out other transitional arrangements, follow those.
  6. Add the charger and vehicle projects to your tracking list and check their status on the platform regularly. Until the final texts are published, the comment drafts should only be used for internal assessment.

Three common mistakes

Mistake one: treating a test report against a recommended standard as proof of conformity with GB 47741-2026. ISO 7176-31, GB/T 18029.25 and GB 47741-2026 are different documents. Whether one can stand in for another depends on the requirements in the full text of GB 47741-2026, not on how similar the titles look.

Mistake two: looking only at the publication date. GB 47741-2026 was published on 25 May 2026 and takes effect on 1 June 2027. The two dates mean different things for production, stock and contract planning.

Mistake three: treating a comment draft as the final standard. As of 13 November 2026 the charger and vehicle projects were still out for public comment. Their clauses may change before submission for approval, and their implementation dates cannot be set until they are published.

How to look up GB 47741-2026 and battery-related standards in our database

The "Standards index" page of our testing database is organised by publishing body. As of 13 November 2026, it lists 4,792 medical device standards with pages, including 224 with the GB prefix and 628 with the GB/T prefix.

As of 13 November 2026, GB 47741-2026 had not yet been added to our standards library. To check its status and full text, use the GB 47741-2026 detail page on the National Public Service Platform for Standards Information. The two projects can be searched by plan number on the same platform, for example the charger project 20254990-Q-339 and the vehicle project 20263144-Q-314. These pages show project progress, the assignment date and links to the comment drafts.

Related recommended standards can be searched by number on our testing search page. For example, entering "18029-25" brings up the GB/T 18029-25 record, which shows the number, editions, effective date in China and the official channel for obtaining the text. Standard texts are copyrighted. Our site provides bibliographic records and official links only, not full-text downloads.

Our regulations database organises medical device regulations by country and region. As of 13 November 2026, the China (National Medical Products Administration) entry is marked "in progress". For a national standard such as GB 47741-2026, which comes under MIIT, we recommend tracking it directly on the National Public Service Platform for Standards Information.

Testing evidence and SUNGO

Neither GB 47741-2026 nor the two mandatory standard projects fall within the accreditation scope of either SUNGO laboratory, and this article does not claim that SUNGO can test or report against them. For the related recommended and international standards, Hefei SUNGO Medical Technology Co., Ltd. holds the following scope (check the certificate schedules for the specific items):

  • CNAS (L24279): 7 items of ISO 7176-25:2022 and 8 items of ISO 7176-31:2023. For GB/T 18029.25-2022, only Clause 5 (battery charger) is accredited, with electromagnetic compatibility excluded.
  • CMA (260015342945): 8 items of ISO 7176-31:2023. ISO 7176-25 and GB/T 18029.25 are not included.
  • IAS (TL-1119): ISO 7176-25, ISO 7176-31 and GB/T 18029.25, each as a whole standard, listed without edition years.

CNAS and IAS are both signatories to the ILAC MRA. The same standard number can carry different edition years and items on different certificates, so check the schedules item by item rather than relying on the standard number alone. For an overview of the electric wheelchair testing service, see the electric wheelchair testing page. For background on battery logistics before testing, see Powered Wheelchair Battery Shipping and Test Submission.

Frequently asked questions

When does GB 47741-2026 take effect?

GB 47741-2026 was published on 25 May 2026 and takes effect on 1 June 2027. Any transitional arrangements follow the official text and announcements from the competent authority.

Where can I read the full text of GB 47741-2026?

Open the GB 47741-2026 detail page on the National Public Service Platform for Standards Information and click "view text". It leads to the national standard full-text page, which offers "online preview" and "download standard" options. Our site provides the bibliographic record only, not the text.

When will the Chinese mandatory standards for electric wheelchair chargers and electric wheelchairs take effect?

As of 13 November 2026, both were still national standard projects out for public comment. Their project pages state that each is planned to take effect 12 months after publication. The publication dates are not yet known, so the implementation dates cannot be worked out. Check the platform for progress.

Can an existing ISO 7176-31 report be used for GB 47741-2026?

Do not assume so. Conformity with GB 47741-2026 is judged against its full text, so compare the text item by item and identify any requirements your existing report does not cover. If in doubt, confirm with the competent authority or the body named in the standard.

Do export-only electric wheelchairs need to meet GB 47741-2026?

Article 26 of the Standardization Law states that the technical requirements for exported products follow the contract. If the same model is also sold in China, or if the scope of the standard says otherwise, it needs to be checked separately against the full text and the competent authority's interpretation.

GB 47741-2026 has been published and its implementation date is fixed, while the charger and vehicle standards are still waiting for final texts. What manufacturers can do now is read the full text, map out which batteries and chargers go with which models, collect evidence from suppliers, and plan the changeover around the implementation date. This article is based on official public information available as of 13 November 2026. The latest documents from the regulator prevail.

About SUNGO Lab: What We Test

SUNGO Lab is made up of two independent companies, Shanghai SUNGO Medical Technology Co., Ltd. and Hefei SUNGO Medical Technology Co., Ltd., and focuses on medical device testing. Our core service lines are:

  • Wheelchair and mobility aid testing (Hefei laboratory): manual and powered wheelchairs, scooters, walking aids and crutches to the ISO 7176 series (excluding Part 19 crash testing and Part 20 standing wheelchairs), ANSI/RESNA WC-1/WC-2, EN 12183, EN 12184, the GB/T 18029 series and GB/T 12996-2024. Which accreditation (CNAS, CMA or IAS) covers each standard is as listed in our certificate scopes. See Wheelchair testing for FDA 510(k) and RESNA.
  • Medical electrical safety and EMC (Hefei laboratory, IAS accredited, certificate TL-1119): IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, IEC 60601-1-11 and ISO 80601-2-69, with the corresponding Chinese standards GB 9706.1 and YY 9706.102.
  • Testing for registration in China and overseas: we plan testing to the standards your target market requires (NMPA, FDA 510(k), EU CE marking and others) and issue the test reports for your submission; whether a report is accepted is decided by the regulator.

Our Shanghai laboratory also tests medical masks, gloves, surgical gowns, sterile packaging and sterilization-related items. CNAS and IAS are both signatories to the ILAC MRA. Send your product, target markets and standards through our contact page and we will confirm which laboratory and which accredited scope covers each test.